Board makes every 5 to 10 minutes restart

Created Sat, 02 Jan 2016 17:22:01 +0000 by MRuoss


MRuoss

Sat, 02 Jan 2016 17:22:01 +0000

Good day community, I'm busy working on a project with a Cerebot MX7 Pro. It's me now noticed that the board so every 5 to 10 minutes restarts. This is not intended by me. I would be happy to send you my project to be ruled by an error on the board.

I am using MPLAB X 3.15 with the XC32 1.40 on the PowerDebug USB connection.

I hope for an insightful answer or input.


tom21091

Tue, 19 Jan 2016 01:22:46 +0000

Hi MRuoss,

I was able to replicate your problem, but I am still looking into why it restarts periodically. Have you had any breakthroughs since you asked the question?

Thanks,

Tommy


cristian.fatu

Tue, 19 Jan 2016 08:45:17 +0000

While investigating this issue through Digilent Technical Support channel, we were answered by him that he found the cause for this behavior:

#pragma config FWDTEN = OFF // Enable Watchdog Timer #pragma config WDTPS = PS1024 // Watchdog Timer post-scaler